Please ACCURATELY Fill in the Information Below to Start the Design Process
This is the Company Name that will Print in the Reports
If You Have a Mobile Phone Number Please Enter it Here
Please Enter Your Fax Number
If You Have a Website Please Enter the URL
Please Enter the Address for Billing Purposes or the Address of the Contractor
The Actual Address of the Project.
Please Enter the Compass Direction the Project Faces
Please Enter the Altitude Above Sea Level of the Project
Please Enter the Jurisdiction Reviewing the Design
Please Enter the Current Codes Being Enforced
Reports Required and System Type
Please Select ALL that APPLY
Please Select All Other Reports Required
The Number of Furnaces or Air Handlers Requested
The Number of Zone DAMPERS Required for the Furnace or Air Handler
Number of Hydronic Zones Required
Please Select the Furnace Manufacture Name - If "N/A" is Selected, Carrier or Lennox will be used. If "Other" is selected Please enter Manufacture below.
The Manufacture Model# ex. Lennox "SLP98" or Carrier "59MN7A"
Please Select the Boiler Manufacture Name. If "N/A" is selected Triangle Tube will be used. If "Other" is selected please enter Manufacture Name below.
The Manufacture Model# of the Boiler ex. Triangle Tube "Solo 95"
Select the Minimum Efficiency Required
Please Select ALL Options Required
Each Section has a Number and Letter. The Letter corresponds to the Figure and the Number to the Component. Example: #1a = Figure "a" - Component #1.
Please Enter the Type of Soli
Below Grade Walls.
Structural Wall Thickness ONLY. Do not enter total wall thickness.
Insulation in a Hollow Block Wall or IFC Panels
Framing for Below Grade Foundation INTERIOR Walls. Do NOT Included Interior Basement Framing.
Insulation for Below Grade Foundation INTERIOR Basement Walls. Do NOT Included Interior Basement Framing. Code Minimums Noted.
Insulation Under Basement Slab. NOT for Structural Floors.
Insulation For Basement Slab Edges at or Above Grade. NOT for Structural Floors. Code Minimums Noted.
Insulation Depth From Top of Slab, at or Below Grade. Code Minimums Noted.
Insulation Under Basement Structural Floor. Under Floor OR Crawl Space Walls must be insulated.
Each Section has a Number and Letter. The Letter corresponds to the Figure and the Number to the Component. Example: #1c = Figure "c" - Component #1.
Insulation on the EXTERIOR of the Below Grade Crawl Space Foundation Wall
Insulation on the INTERIOR of Below Grade Crawl Space Foundation Wall. Code Minimum Noted.
Enter any Below Grade Basement Construction Not Found Above. Please be specific.
Each Section has a Number and Letter. The Letter corresponds to the Figure and the Number to the Component. Example: #1b = Figure "b" - Component #1.
For Log Homes Select "None"
Above Grade Basement Wall Exterior Sheathing
Insulation on the EXTERIOR of Above Grade Basement Walls.
Above Grade EXTERIOR Basement Wall Type
Framing for Exterior Above Grade Basement Walls. Do NOT included Interior Basement Framing.
Insulation in the Above Grade EXTERIOR Basement Walls. Do NOT Include the Interior Basement Walls. Code Minimums Noted.
Enter any Above Grade Basement Construction Not Found Above. Please be specific.
Insulation on the EXTERIOR of the Main Floor Walls
Framing for EXTERIOR Main Floor Walls. Do NOT Included INTERIOR Framed Walls.
Insulation in the Cavities of the Main Floor EXTERIOR Walls. Code Minimums Noted.
Insulation Value in Floors Over Unconditioned Areas or Outside Air. Code Minimums Noted.
Enter any Main Floor Construction Not Found Above. Please be specific.
Each Section has a Number and Letter. The Letter corresponds to the Figure and the Number to the Component. Example: #1d = Figure "d" - Component #1.
The Type of Roofing Material to be Used
Color of the Roofing Material
Foam Insulation Installed ABOVE the Roof Decking
Insulation Value Installed in the Flat Roof - Ceiling Combination. Code Minimums Noted.
Insulation Value Installed in Vaulted Ceilings. Code Minimums Noted.
Insulation Value Installed Flat on the Ceiling in the Attic. Code Minimums Noted.
Enter any Ceiling Construction Not Found Above. Please be specific.
Weighted Average Values Example for U-Factor & SHGC: Sq.Ft Glass @ U-Factor of 0.35 = 100 x 0.35 = 35 Sq.Ft Glass @ U-Factor of 0.30 = 150 x 0.30 = 45 Sq.Ft Glass @ U-Factor of 0.25 = 75 x 0.25 = 18.75 Add up the Sq.Ft. - Add up the sum of Sq.Ft. x U-Factor (100 + 150 + 75) = 325 Total Sq.Ft. of Glass (35 + 45 + 18.75) = 98.75 Sum of Sq.Ft. x U-Factor Weighted Average Value = (98.75 / 325) = 0.304 or 0.30
Windows & Glass Doors U-Factor Code Minimums: 2006-2009 = 0.35 2012 = 0.32 Skylights U-Factor Code Minimums: 2006-2009 = 0.60 2012 = 0.55
Enter Average Weighted U-Factor using formula above. Window Supplier can Typically Supply this information.
Enter Average Weighted SHGC using formula above. Window Supplier can Typically Supply this information.
Enter Skylights U-Factor. Window Supplier can Typically Supply this information.
Enter Skylights SHGC. Window Supplier can Typically Supply this information.
Please Review Your Entries and Upload the Required Files to Complete the Project Information Form.
1) Floor Plans (DWG Format) 2) Room Names - Ceiling Heights - Windows & Door Sizes 3) Sectionals & Elevations (DWG or PDF Formats) 4) Site Plan (DWG or PDF Formats) 5) Please Bind ALL X-Refs or Supply the Necessary Files 6) Any Other Files Which Are Relevant to the Design You can select multiple files using the standard Windows 'Ctrl' or 'Shift' Keys. Each Click on the Browse Button will add additional files to the Upload List.